background image

Digital Techniques Lab 

                                                                                                                               Experiment one 

 

Nineveh University   
College: Electronics Eng. 
Dept.: Systems & Control Eng.  
 

Digital Logic Lab KL-300 

The KL-300 Digital Logic Lab is a self-contained system suitable for everyone engaged in digital 

logic  experiments.  All  necessary  equipment  for  digital  logic  experiments  such  as  power 

supplies, signal generators, switches and displays are installed on the main unit KL 31001. 

Specifications: 

  Power Supply 

1. Fixed Power 

Range: +5V/1.5A; -5V/0.3A; ±12V/0.3A 

 

2. Adjustable Power                      

 

(1) Range: +1.5V →+15V 

(2) Maximum Output Current: 0.5A 

  Signal Generators 

All signal generators have TTL and CMOS level output terminal. TTL has a fixed 5V output while 

CMOS level output range from +1.5V to +15V. 

1. Standard Frequency 

 

      Frequency: 1MHz, 50/60HZ, 1Hz 


background image

2. Clock Generator 

Six Ranges, 1Hz 

– 1MHz, Continuously Adjustable. 

  Data Switches 

1.  Two 8-bit DIP switches. 

 

2.  Four toggle switches. 

 

  Pulse Switches 

Two toggle switches with Q and Q 

  Thumbwheel Switches 

Two digits BCD output 

 


background image

  Line Signal 

Frequency: 50/60 Hz 

Output Voltage:  6V r.m.s 

  Logic Indicators 

16 independent LED for "Hi-Low" logic state indication 

 

  Digital Displays 

4 independent 7-segment LED displays Input with 8 • 4 • 2 • 1 BCD code. 

A, B, C and D are the Input terminals. Note that all terminals use TTL signals as input voltages.  

 

Experimental Procedure 

1.  Connect DIP switch first then data switch terminal to a Logic indicator and change/monitor 

the switch state. 

2.  Connect a pulse switch terminal to a Logic indicator then change and monitor the switch 

state. 

3.  Connect a Multimeter to a TTL toggle switch and measure the output voltage. 


background image

4.  Connect a Multimeter to a CMOS toggle switch and measure the output voltage. 

5.  Connect the TTL input switches (SW3, SW2, SW1 and SW0) to LEDS (L3, L2, L1 and L0) then, 

change the input from (0000 to 1111) and show the outputs on the LEDS.  
 

6.  Connect the  DIP1  input switches  (0  to  7)  to the output  LEDS  (L0 to  L7) then  display the 

following values in binary (9, 33, 69, 106, 250).  
 

7.  Connect toggle  Switch  to a  digital  display  then change the  input  and record  the output 

according to the table below: 

DISPLAY 

DISPLAY 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8.   Connect the thumbwheel switches common inputs (x1 and x10) to the power supply (+5V). 

connect the output of x1 to the 7-segment digital display D0 and to LEDs (L0, L1, L2 and L3). 

Also connect the output of x10 to the 7-segment digital display D1 and to LEDs (L4, L5, L6 

and L7). Now change the input form (00 to 25) and show the results on 7-segments and 

LEDS at the same time. 

Questions 

Q1) What is TTL and CMOS voltage level? 

Q2) How could you change the CMOS output level? 

Q3) What is the difference between CMOS and TTL circuits? 

Q4) How do the 

Digits 10-14 are displayed

 on the digital display? 

Q5) What happens if you connect a CMOS input signal to the digital display? 